Seitenansicht 3
22
3/8
(568mm)
electrical collar
15
1/4
(388mm)
8”
(203mm)
8
1/8
(206mm)
16” (406mm)
anchor point
anchor point*
stud stud
anchor point*
anchor point
electrical box
1. Afxing the Towel Warmer to the Wall (continued)
Note: Dimensions shown are distances between the center of anchor
points. This example shows 16 inches on center construction. Your
situation may vary depending on stud spacing.
WARNING: Locations of electrical box and anchor points may vary.
Measure all dimensions prior to rough-in and installation.
Diagram A: Anchor Points and Electric Box Location
Note: For hardwired model only, electrical box must be securely attached to a
stud. Plug-in model only must be installed less than 6 feet (183cm) from
properly grounded outlet. Do NOT use an extension cord.
* Note: Anchor points must be attached to a stud.